Incinerateur
Basic Info. Export Markets:Global Additional Info. Trademark:clover Origin:China Production Capacity:1000 Sets Per Year Product Description Key Attributes: * All models with Dual combustion room. *...
Basic Info. Export Markets:Global Additional Info. Trademark:clover Origin:China Production Capacity:1000 Sets Per Year Product Description Key Attributes: * All models with Dual combustion room. *...
on incinerator burner, there's 1 oil pump and have two tube for Suction Line and Return Line.
Smallest waste incinerator for small hospital average 10kgs per hour. with double(2) sets burner. Equipment Technical Specifications Model YD-10 Feed Capacity Typical 20 kgs per...
Ability of destruction in weight: 60 Kg/h. It should be in a position to operate not less than 10 hours/day This incinerator must be able...
Ability of destruction in weight: 60 Kg/h. It should be able to work less 10 hours/day This incinerator must have the ability to destruct all...
Mobile Diesel Fired Incinerator in container, supplied with the following specifications: complete with constant ventilation fans for extraction, factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. Fully containerised mobile waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner b. Dedicated independent fan system, damper controlled. c. Thermostatic Sensor d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner...
Mobile Diesel Fired Incinerator in container, supplied with the following specifications: complete with constant ventilation fans for extraction, factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. Fully containerised mobile waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner b. Dedicated independent fan system, damper controlled. c. Thermostatic Sensor d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner...
Medical Waste Incinerator Purpose For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement. -Waste from health care activities -Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents. -Pathological waste, human fragments, blood, fetus, all body fluids, human tissues. -Sculpts, needles, infusion sets, blades, glass -Pharmaceutical waste. -Chemical waste laboratory reagents, disinfectants -Expired drugs. -Low radiation radioactive element. Medical waste incinerator: – Ecological Requirement – No odor -No fume -Definitive treatment of waste Medical waste incinerator: – Manufacturing Standards -UL,CE, ASME, ISA EURO emission standard 1.Medical waste incinerator Construction – CS plate shells, FB reinforcement, cast refractory linings, Insulation and 14 gage aluminum jacket. Type of fuel – Oil fired (Diesel) Burning Capacity – 250kg/hr and moisture up to 80%. Duration -8-16/Continuous Average fuel consumption – Very little as much as possible Control Type – PLC based operation...
Medical Waste Incinerator Purpose For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement. -Waste from health care activities -Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents. -Pathological waste, human fragments, blood, fetus, all body fluids, human tissues. -Sculpts, needles, infusion sets, blades, glass -Pharmaceutical waste. -Chemical waste laboratory reagents, disinfectants -Expired drugs. -Low radiation radioactive element. Medical waste incinerator: – Ecological Requirement – No odor -No fume -Definitive treatment of waste Medical waste incinerator: – Manufacturing Standards -UL,CE, ASME, ISA EURO emission standard 1.Medical waste incinerator Construction – CS plate shells, FB reinforcement, cast refractory linings, Insulation and 14 gage aluminum jacket. Type of fuel – Oil fired (Diesel) Burning Capacity – 250kg/hr and moisture up to 80%. Duration -8-16/Continuous Average fuel consumption – Very little as much as possible Control Type – PLC based operation...
Operating period Anticipated daily period 8 hours Maximum operating period 12hours Chamber Should be refractory lined to the following standards, hearth and lower section of chamber walls. Hot face materials Super dusty firebricks Limiting continuous service limit 1500°c Thickness 100mm Thermal conductivity 1.3W/mk Insulation Calcium silicate Limiting continuous service limit 1000°c Thickness 25mm Thermal conductivity 0.095w/mk Chimney/stack Should be manufactured from refractory lined mild steel or high quality air cooled stainless steel. The chimney/stack should have a minimum height of 10 meters above ground level Ignition burners Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves, fan and motor Maximum rating : at least 450kw/hour Burner: arranged for on/off operation Maximum consumption : at least 6litres per hour Average consumption : at least 3litres/hour After burner Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves fan and motor....