One (MAIN) chamber only, with two doors Doors with hinges at the center LPG combustible mainly After burner and chimney don′t change MAIN Chamber dimensions [LxWxH]: 2.2m x 4.5m x 2.8m, so we can put two containers within the MAIN chamber Ok per your comment, refractory concrete and fire brick inside the chamber; feed door with refractory concrete Burning Rate:47.5–50kg/hour Minimum Operating Temperature:850o C(primary combustion) Maximum Operating Temperature:1450 oC(Afterburner chamber) Secondary Burning Capacity:Compulsory Density Insulation:20mm High Refractory Casting:Minimum 65mm Heavy duty refracting lining to withstand:1500 oC Average burn out time :maximum:3 hrs Fuel type:Diesel Fuel Consumption in L/hr:7.5 to 9 Residence time in secondary chamber:2sec Residue ash post 100kg:Max 3.8kg 1) This type is suitable for medical waste, but how many kilos can be put in the incinerator in one time 2) Q: Operation and maintenance costs, these costs are based on?? What if we use it every day?? 3) How many hertz do we need for this type of incinerator 4) Where is the oil tank in the incinerator? 5) Is it possible to build in not the standard accessories but the high proof accessories? 6) What are the costs when shipment is to Surinam/South America 7) How will the inicinerator be delivered? Partly installated or do we have to install it completly? ...